Expertise in energy installations and combined heat and power
Availability, efficiency and maintenance of CHP plants and energy installations, tested against contract and data
A CHP plant underperforms when its availability or output falls below the values in the contract, measured using the formula set out in that contract. Who is liable follows from the cause: failure to maintain on the part of the maintenance contractor, operating conditions on the operator's side, or a design or material defect. The installation's telemetry and alarm history decide, not one party's theory.
Who is it for
Operators of CHP plants and energy installations in industry, healthcare, buildings and horticulture, with an installation that is less available or yields less than promised.
Installers, maintenance companies and manufacturers who want to show that they fulfilled their contract or that the cause lies on the operating side.
Lawyers, insurers and courts looking, in an energy dispute, for an expert who understands the engines as well as the contracts and the data.
How it works
- Securing the data. Telemetry, alarm history, logs and work orders over the entire term, and a system image of the control system where possible.
- Scrutinising the contracts. Maintenance contracts, guarantees and SLAs clause by clause: what was promised, what is excluded, which measurement formula applies.
- Recalculating performance. Availability and output using the contract formula, per installation and per year, alongside the alarm history and the work orders.
- Testing the causes. Every theory, including our own, against the installation's own data: does the alarm occur where the theory predicts it, and not where it does not.
- Report. Performance shortfall, cause, each party's share from a technical point of view, and the loss in production and certificates.
What you can expect from us
Knowledge of the installations. Gas engine CHP plants, fuel cells, heat exchangers, controls and telemetry; overhauls, maintenance intervals and what an engine should do after an overhaul.
Contract and data. An availability guarantee is only worth something if it is measured using the correct formula. We recalculate the metric where it is applied differently from what the contract prescribes, and present that calculation in such a way that everyone at the table can check it.
Empirical rebuttal. An opposing party that invokes water quality is answered with the alarm history: if the water alarm only occurs at the best-performing installation, it does not explain the worst one.
The full loss. Production, additional costs, and the certificates and emission obligations attached to the installation.
Costs
An hourly rate for file review, data analysis, site visit and report, plus travel costs and the cost of measurements or laboratory analyses, excluding VAT. An estimate in hours in advance; in the case of a court appointment, in accordance with the rules on the advance on costs and the deposit with the court registry.
Standards and legislation
- Maintenance contracts, SLAs and warranty terms: availability thresholds, notification periods, reporting obligations, overhaul exclusions, operating conditions such as the heating water quality.
- VLAREM II: emission conditions and measurement obligations for stationary engines; the associated emission reports.
- CHP certificates and the related measurement and reporting rules.
- Manufacturer's instructions for maintenance intervals, overhauls and operating conditions.
- Belgian Judicial Code, Article 962 et seq., in the case of a court appointment.
Questions about energy
How do you measure the performance of a CHP plant?
On the basis of the data the installation records itself: electricity and heat produced, gas consumption, running hours, start attempts, alarms. We calculate availability using the contract formula, for example on nominal running hours. Where necessary we supplement this with emission measurements and an output analysis.
Which guarantees apply to energy installations?
Whatever the contract says: availability guarantees with a threshold, preventive and corrective maintenance, notification periods, reporting obligations, exclusions for overhauls or for operating conditions such as water quality. In addition, the statutory warranty and the manufacturer's instructions. We set them against the facts clause by clause.
What if there is a dispute with the installer?
First secure the data: telemetry, alarm history, work orders, analyses. We then test the performance against the contract and the causes against the history. We support you as technical adviser (party expert) in an amicable or court procedure, or act as independent expert for both parties.
Do you also review contracts and SLAs?
Yes, technically: are the guarantees measurable, is the measurement formula unambiguous, are the obligations on both sides achievable and verifiable. Both before signing and in a dispute. We leave the legal characterisation to your lawyer.
Which certificates and regulations are relevant?
A qualifying CHP plant receives CHP certificates (warmtekrachtcertificaten) for the primary energy savings it achieves, during the support period after commissioning. Separately, the emission limit values and measurement obligations of VLAREM II apply. An installation that is standing still can therefore also miss out on certificates, as long as it falls within that support period. That loss belongs in an assessment of damages.
Related
Discuss your case
A first conversation is free of obligation. Book a time straight away, or send us your question through the form.
Last updated: